Difference between revisions of "Telecom"
From Eth0Wiki
m |
(reformatted to wiki formatting. cleanup) |
||
Line 1: | Line 1: | ||
− | + | =Telecom Page= | |
− | |||
− | |||
− | |||
− | |||
− | + | == Team Phone == | |
− | Who can will help | + | Who can/will help: |
− | Boelens | + | * Boelens |
+ | * psy | ||
+ | * gido-e | ||
− | + | == Brainstorm == | |
− | |||
− | |||
− | < | + | * Phone numbers can be max 6 digits. :-) (still to test) |
+ | * Need table / application to sign up for phone nr.<br> | ||
− | + | == Hardware around == | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | === Siemems 150E PRO pbx === | |
− | + | [[Image:Shpro.jpg]] | |
− | + | [[Image:Cabinet.jpg]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | ---- | + | specs: |
+ | * CBMOD processorcard + CGM "Clock Module Generator" | ||
+ | * SLMO24 board S30810-Q2901-X for connection of 24 digital OPTISET/OPTIPOINT stations | ||
+ | * SLMO24 board S30810-Q2901-X for connection of 24 digital OPTISET/OPTIPOINT stations | ||
+ | * Cordless SLC16 CMI Card S30810-Q2922-X-0 for connection of 16 Base Stations Cordless V2.2 | ||
+ | * SLA16N Analog Suscriber Interface (S30810-Q2929-X100) ,16 circuits /analog stations | ||
+ | * SLA16N Analog Suscriber Interface (S30810-Q2929-X100) ,16 circuits /analog stations | ||
+ | * STMD 8 isdn connections S0 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | === Siemens 3550 pbx === | |
− | |||
− | |||
− | |||
− | + | specs: | |
+ | * 8 x digital lines | ||
+ | * 4 x analog lines | ||
+ | * 1 x HXGM IP card | ||
+ | * 1 x 2 ISDN trunk card | ||
− | + | === Other hardware === | |
− | |||
− | |||
− | |||
− | + | * 8 dect base stations 2/2 | |
− | + | * patch rack Cisco | |
− | + | * 2 x 50 port cat3 patch panels | |
− | + | * 8 x cablu for 16 connections per cable | |
− | + | * 12 x Siemens Hicom Digital phones. | |
− | + | * 1 x Patch rack for mounting patch pannels | |
− | + | * 26 x Philips Dect set. | |
− | + | * 180 x Siemens Dect sets | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | == Hardware needed == | |
− | + | * HXGM2 card for Siemens Hicom PRO | |
− | Setup Dect / Gap/ Voip network coverage on the field. | + | * Expansion box for Siemens PRO |
− | + | * Additional SLC16 cards for the PRO | |
− | + | * 4 x patch pannels cat3 for telephone. | |
− | First access to system 11-02-2010 | + | * 10 x Cat3 cables 300 meters for base stations. |
− | First 64 Ports have been patched. | + | * Phone cables or cat 5 for phones. (Multi cable?) |
− | YeP fist Base Station has green light. \0/ 12-02-2010 | + | * Battery packs for Siemens dect sets. |
− | First call made with fixed phone 14-02-2010 | + | * Battery covers for Siemens dect sets. |
− | + | ||
+ | |||
+ | == Software projects == | ||
+ | * Software Programmers needed for statistics read out of central. | ||
+ | * DB for users to sign up for phone nr. | ||
+ | * PHP programmers wanting to program agains the serial interface. | ||
+ | * Connect central data card to VOIP server(s). | ||
+ | |||
+ | |||
+ | == What we can / will do on summer edition == | ||
+ | |||
+ | * Setup Dect / Gap/ Voip network coverage on the field. | ||
+ | |||
+ | |||
+ | == Notes of Mr Boelens :) == | ||
+ | |||
+ | (which system you're talking about? please move the info to the correct paragraph) | ||
+ | |||
+ | * First access to system 11-02-2010 | ||
+ | * First 64 Ports have been patched. | ||
+ | * YeP fist Base Station has green light. \0/ 12-02-2010 | ||
+ | * First call made with fixed phone 14-02-2010 |
Revision as of 14:41, 2 March 2010
Contents
Telecom Page
Team Phone
Who can/will help:
* Boelens * psy * gido-e
Brainstorm
- Phone numbers can be max 6 digits. :-) (still to test)
- Need table / application to sign up for phone nr.
Hardware around
Siemems 150E PRO pbx
specs:
* CBMOD processorcard + CGM "Clock Module Generator" * SLMO24 board S30810-Q2901-X for connection of 24 digital OPTISET/OPTIPOINT stations * SLMO24 board S30810-Q2901-X for connection of 24 digital OPTISET/OPTIPOINT stations * Cordless SLC16 CMI Card S30810-Q2922-X-0 for connection of 16 Base Stations Cordless V2.2 * SLA16N Analog Suscriber Interface (S30810-Q2929-X100) ,16 circuits /analog stations * SLA16N Analog Suscriber Interface (S30810-Q2929-X100) ,16 circuits /analog stations * STMD 8 isdn connections S0
Siemens 3550 pbx
specs:
* 8 x digital lines * 4 x analog lines * 1 x HXGM IP card * 1 x 2 ISDN trunk card
Other hardware
- 8 dect base stations 2/2
- patch rack Cisco
- 2 x 50 port cat3 patch panels
- 8 x cablu for 16 connections per cable
- 12 x Siemens Hicom Digital phones.
- 1 x Patch rack for mounting patch pannels
- 26 x Philips Dect set.
- 180 x Siemens Dect sets
Hardware needed
* HXGM2 card for Siemens Hicom PRO * Expansion box for Siemens PRO * Additional SLC16 cards for the PRO * 4 x patch pannels cat3 for telephone. * 10 x Cat3 cables 300 meters for base stations. * Phone cables or cat 5 for phones. (Multi cable?) * Battery packs for Siemens dect sets. * Battery covers for Siemens dect sets.
Software projects
- Software Programmers needed for statistics read out of central.
- DB for users to sign up for phone nr.
- PHP programmers wanting to program agains the serial interface.
- Connect central data card to VOIP server(s).
What we can / will do on summer edition
- Setup Dect / Gap/ Voip network coverage on the field.
Notes of Mr Boelens :)
(which system you're talking about? please move the info to the correct paragraph)
- First access to system 11-02-2010
- First 64 Ports have been patched.
- YeP fist Base Station has green light. \0/ 12-02-2010
- First call made with fixed phone 14-02-2010